{"product_id":"hylb-867-replacement-battery-edanins-ecg-monitor","title":"HYLB-867 Replacement Battery 14.4V 4400mAh Li-ion for EDANINS ECG Monitor","description":"\u003ch2 class=\"desc-tb-title-2\"\u003eProduct Specification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Model:\u003c\/strong\u003e HYLB-867\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 14.4V (also compatible with 14.8V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 4400mAh (63.36Wh)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Type:\u003c\/strong\u003e Li-ion (Lithium-Ion)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell Configuration:\u003c\/strong\u003e 4S2P (8 premium cells)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell Brand:\u003c\/strong\u003e Samsung INR18650 (Genuine OEM cells)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 86 × 34 × 44 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 380 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCycle Life:\u003c\/strong\u003e Up to 500 charge\/discharge cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging Voltage:\u003c\/strong\u003e 14.4V (CC\/CV mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging Current:\u003c\/strong\u003e 1A (recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging Time:\u003c\/strong\u003e Approx. 4 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e 0 to 45 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Replacement Battery (100% Brand New, 1-year warranty!)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"desc-tb-title-2\"\u003eReplace Part Numbers\u003c\/h2\u003e\n\u003cul class=\"desc-tb-flex-2\"\u003e\n\u003cli\u003eHYLB-867\u003c\/li\u003e\n\u003cli\u003eHYLB-1188\u003c\/li\u003e\n\u003cli\u003eHYHB-1188\u003c\/li\u003e\n\u003cli\u003eHYHB-1172\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"desc-tb-title-2\"\u003eCompatible Device Models\u003c\/h2\u003e\n\u003cul class=\"desc-tb-flex-3\"\u003e\n\u003cli\u003eEDANINS ECG Monitor Series\u003c\/li\u003e\n\u003cli\u003eEDANINS ECG-12A\u003c\/li\u003e\n\u003cli\u003eEDANINS ECG-12B\u003c\/li\u003e\n\u003cli\u003eEDANINS ECG-12C\u003c\/li\u003e\n\u003cli\u003eEDANINS Patient Monitor Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"desc-tb-title-2\"\u003eBuilt-in Safety Protection\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercharge Protection:\u003c\/strong\u003e 4S BMS limits charge to 16.8V max to protect all 8 cells from overvoltage damage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverdischarge Protection:\u003c\/strong\u003e Cuts off at 12.0V to prevent permanent cell degradation during deep discharge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverheat Protection:\u003c\/strong\u003e Multi-point thermal sensing across the 8-cell pack — critical for continuous ECG monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Limits discharge current to protect ECG device electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection:\u003c\/strong\u003e Instant cutoff to prevent electrical failure during patient monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"desc-tb-title-2\"\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 9001:2015:\u003c\/strong\u003e Quality management system certified manufacturing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marked for medical device accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Environmentally compliant, lead-free materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUN38.3:\u003c\/strong\u003e Certified safe for air and sea freight transport\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 62133:\u003c\/strong\u003e International safety standard for portable secondary cells\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories safety certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for UK market entry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Federal Communications Commission compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMSDS:\u003c\/strong\u003e Material Safety Data Sheet available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"desc-tb-title-2\"\u003eEngineered for EDANINS Patient Monitors — 63.36Wh of Reliable Power\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEDANINS — A Trusted Global Medical Brand:\u003c\/strong\u003e EDANINS is the diagnostic equipment line of Edan Instruments, Inc. a publicly listed medical device manufacturer founded in 1995. Edan patient monitors and ECG devices are deployed in 170+ countries, trusted by hospitals, clinics, and emergency services worldwide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-Cell 4S2P Architecture:\u003c\/strong\u003e Four series groups deliver stable 14.4V for the monitor's display, ECG module, and SpO2\/NIBP measurement circuits. Two parallel groups provide 4400mAh — nearly double the capacity of standard 2200mAh 4-cell medical batteries like the HYHB-1172 series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSamsung INR18650 Cells Inside:\u003c\/strong\u003e We use genuine Samsung SDI industrial-grade 18650 cells — the same cells trusted by medical device OEMs and power tool manufacturers. Not generic no-name cells. Every cell is traceable to Samsung's factory with consistent low internal resistance and predictable discharge curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e63.36Wh Capacity — Extended Monitoring Sessions:\u003c\/strong\u003e At 4400mAh × 14.4V, this pack provides 63.36 Watt-hours of energy. For a typical EDANINS ECG-12 series monitor drawing 10-15W, that translates to 4-6 hours of continuous battery-powered operation — covering full patient transport, emergency triage, and ward rounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e380g — Firm, Secure, Purpose-Built:\u003c\/strong\u003e Not an afterthought accessory. The 86×34×44mm form factor and 380g weight are specifically engineered to slot securely into EDANINS monitor battery bays. The robust casing protects the 8-cell array from vibration and impact in mobile clinical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"desc-tb-title-2\"\u003eCross-Compatible with Multiple EDANINS Models\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHYLB-867\u003c\/strong\u003e — Primary model number for 4400mAh 8-cell packs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHYLB-1188 \/ HYHB-1188\u003c\/strong\u003e — Alternative part number for higher-capacity EDANINS ECG batteries; electrically compatible (same 14.4V platform, connector interface)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHYHB-1172\u003c\/strong\u003e — 2500mAh variant for ECG-1A\/ECG-3A devices; 14.4V compatible. If you need a lighter 2500mAh battery, check our \u003ca href=\"\/en-nl\/collections\/edanins-ecg-monitor-batteries\"\u003eEDANINS collection\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECG-12A \/ ECG-12B \/ ECG-12C:\u003c\/strong\u003e 12-channel resting ECG machines — the most common deployment for HYLB-867 in outpatient cardiology departments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14.4V and 14.8V are interchangeable:\u003c\/strong\u003e Both voltages represent the same 4S Li-ion platform. 14.4V = nominal (3.6V\/cell × 4), 14.8V = nominal (3.7V\/cell × 4). The actual operating voltage range (12.0-16.8V) is identical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"desc-tb-title-2\"\u003eInstallation \u0026amp; Maintenance Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Charge:\u003c\/strong\u003e Fully charge before first use. New Li-ion 8-cell packs require 1-2 full cycles to calibrate the BMS fuel gauge for accurate runtime reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Protocol:\u003c\/strong\u003e If not in use for \u0026gt;30 days, store at 40-60% charge (approximately 14.8-15.2V) in a cool, dry environment. Never store fully discharged — this permanently degrades all 8 Samsung cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotation Schedule:\u003c\/strong\u003e For high-usage ECG departments, maintain at least 1 spare battery per 3 ECG-12 series machines. Rotate batteries every 30 days to prevent capacity fade from idle storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Care:\u003c\/strong\u003e Before installing, visually inspect the battery connector pins for corrosion, bending, or debris. A loose contact causes intermittent power — unacceptable during ECG recording.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Timing:\u003c\/strong\u003e Replace when runtime drops below 70% of original (approx. 3,000mAh remaining) or after 500 cycles — whichever comes first. Continuing use beyond this degrades ECG waveform accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"desc-tb-title-2\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Will this work with my EDANINS ECG-12A?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The HYLB-867 14.4V 4400mAh battery is directly compatible with EDANINS ECG-12A, ECG-12B, and ECG-12C models. It is also cross-compatible with ECG-1A and ECG-3A devices when using the 14.4V battery bay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How does this compare to HYHB-1172 (2500mAh)?\u003c\/strong\u003e\u003cbr\u003eA: HYLB-867 has 76% more capacity (4400mAh vs 2500mAh), approximately 1.5-2x longer runtime, and uses 8 Samsung cells vs 4 cells in HYHB-1172. If your workflow requires extended battery operation (ward rounds, transport), choose HYLB-867. For lighter use, HYHB-1172 is available in our \u003ca href=\"\/en-nl\/collections\/edanins-ecg-monitor-batteries\"\u003eEDANINS collection\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is 14.4V the same as 14.8V?\u003c\/strong\u003e\u003cbr\u003eA: Yes. 14.4V and 14.8V are both standard nominal voltages for 4-series Li-ion packs. The difference is only in the per-cell nominal labeling convention (3.6V vs 3.7V). The actual operating range (12.0-16.8V) and charging profile are identical. This battery is safe and fully functional in any EDANINS monitor rated for 14.4V or 14.8V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long to charge?\u003c\/strong\u003e\u003cbr\u003eA: Approximately 4 hours from empty to full at the recommended 1A charging rate through the monitor's built-in charging circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I buy in bulk for hospital deployment?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Contact our sales team for volume pricing on 10+ units. We support hospital procurement workflows including purchase orders, proforma invoices, and DDP shipping to eliminate customs hassles.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EDANINS","offers":[{"title":"Default Title","offer_id":46316012634284,"sku":"HYLB-867-14.4V-4400mAh","price":101.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0429\/2047\/6834\/files\/EDANINS-HYLB-867-14.4V-4400mAh-Medical-Battery-1.png?v=1779928773","url":"https:\/\/batterymalv.com\/en-nl\/products\/hylb-867-replacement-battery-edanins-ecg-monitor","provider":"BatteryMall.com","version":"1.0","type":"link"}