Product Overview
The Li202SX-7800 replacement battery is made for TSI AeroTrak 9550 Portable Particle Counter. It provides the product-specific electrical characteristics, replacement references and equipment compatibility associated with this battery.
Replacement Battery Specification
| Parameter | Value |
|---|---|
| Battery Model | Li202SX-7800 |
| Capacity | 84.24Wh / 7800mAh |
| Voltage | 10.8V |
| Battery Type | Li-ion |
| Cell | Made in China, high quality guarantee |
| Color | Black |
Replace Part Numbers
- Li202SX-7800
- Li202SX-78C
- Li202SX-7200
- Li202SX-72C
- Li202SX-6600
- Li202SX-66C
- Li202SX-8700
- Li202SX-87C
Compatible Models
- For TSI AeroTrak APC 9310-02 Portable Particle Counter
- For TSI AeroTrak 9500 Portable Particle Counter
- For TSI AeroTrak 9510 Portable Particle Counter
- For TSI AeroTrak 9550 Portable Particle Counter
- For TSI DustTrak II 8530 Dust/Aerosol Monitor
- For TSI DustTrak II 8531 Dust/Aerosol Monitor
- For TSI DustTrak DRX 8533 Aerosol Monitor
FAQ
Q: What equipment is the Li202SX-7800 battery made for?
A: The Li202SX-7800 replacement battery is made for TSI AeroTrak 9550 Portable Particle Counter. Its battery design is intended for the equipment named in this product title, giving the device-specific model reference a clear place in the battery description.
Q: Which devices can use the Li202SX-7800 battery?
A: The Li202SX-7800 battery is associated with TSI AeroTrak APC 9310-02 Portable Particle Counter, TSI AeroTrak 9500 Portable Particle Counter, TSI AeroTrak 9510 Portable Particle Counter, TSI AeroTrak 9550 Portable Particle Counter, TSI DustTrak II 8530 Dust/Aerosol Monitor, TSI DustTrak II 8531 Dust/Aerosol Monitor, TSI DustTrak DRX 8533 Aerosol Monitor. These named devices define the battery's intended equipment group and distinguish this battery from other products that share similar electrical ratings.
Q: What electrical specifications does the Li202SX-7800 battery have?
A: The Li202SX-7800 battery has a voltage of 10.8V, a capacity of 84.24Wh / 7800mAh, a Li-ion chemistry. These characteristics describe the battery's power format and operating specification.
Q: Which replacement references belong to the Li202SX-7800 battery?
A: The Li202SX-7800 battery is associated with Li202SX-7800, Li202SX-78C, Li202SX-7200, Li202SX-72C, Li202SX-6600, Li202SX-66C, Li202SX-8700, Li202SX-87C. These identifiers belong to this battery family and provide the part-number detail needed to distinguish it from other batteries for related equipment.
Q: How does the Li202SX-7800 battery support the named equipment?
A: The Li202SX-7800 battery is designated for TSI AeroTrak 9550 Portable Particle Counter. Its model references, electrical characteristics and equipment-specific compatibility work together to define the battery's intended role in the named device.
Note:
Safety & ComplianceManufactured under strict quality control standards. Complies with international safety requirements such as UN38.3, CE, and RoHS. Follow the device manufacturer’s instructions for safe use.
Professional Installation Recommendation
Installation or replacement should be performed by trained personnel or qualified technicians.
Medical Use Disclaimer
This battery is intended as a replacement power component for compatible medical devices. It is not intended to diagnose, treat, cure, or prevent any medical condition.
Trademark Disclaimer
All brand names, trademarks, and model numbers are used for compatibility reference only and remain the property of their respective owners.
Important Notice
Please verify the battery model, voltage, and connector type before purchasing to ensure compatibility. Contact support if unsure.
Shipping Methods
Overseas Warehouse Shipping Times & Costs
Payment Methods
Paypal

Payments by PayPal, no PayPal account required. Paypal is safe and free for buyers.
PayPal account: Payment@batterymall.com
Account Name: ShenZhen KingSener Science and Technology Co., Ltd
Credit or debit card
VISA, MasterCard, the United States n Express,Maestro & Laser Card, APPLE Pay,etc.
PayPal never shares your financial information with us.
WeChat Pay
Currently only supports QR code payment. Please contact WeChat customer service and go to WeChat App to scan the QR code to complete the payment.
Google Pay
Pay with Google Pay, which is more convenient and faster.
Apple Pay
If you use an Apple device, you can use Apple Pay to pay, which is more convenient and faster.
Bank Transfer
Q&A
Medical Equipment Battery Guide
-
How often should medical device batteries be replaced?Medical device battery replacement intervals depend on equipment type and usage frequency. We recommend the following guidelines:
General Replacement Schedule:
• Replace every 1-2 years, or after 300-500 charge/discharge cycles
• Regardless of apparent battery health
High-Risk Equipment (Strict OEM Compliance Required):
• Life-support devices (ventilators, ECMO machines)
• Emergency equipment (defibrillators, cardiac monitors)
• Anesthesia delivery systems
• Infusion pumps
⚠️ Critical Warning: For medical equipment directly affecting patient lives, you MUST follow the OEM recommended battery replacement schedule. Even if the battery passes functional tests, scheduled replacement prevents power failures during critical moments. -
Are KingSener medical batteries fully certified?Yes. KingSener medical replacement batteries meet multiple international certifications:
Core Certifications:
• ISO 13485 — Medical Device Quality Management System
• IEC 62133 — Safety for Secondary Lithium Cells
• UL94 V-0 — Flame-Retardant Housing Rating
• CE Mark — EU Market Access
• RoHS Compliant — Hazardous Substance Restriction
Why These Matter:
• ISO 13485 ensures full batch traceability under controlled quality management
• IEC 62133 validates battery safety under extreme conditions (overcharge, short circuit, crush)
• UL94 V-0 prevents fire spread in sealed medical equipment enclosures
💡 Note: Our products are positioned as replacement batteries for repair and maintenance. For OEM new equipment manufacturing, contact us for customized compliance solutions. -
How should I store backup medical batteries for emergencies?Proper storage directly affects battery lifespan and emergency reliability:
Standard Storage Conditions:
• Charge State: 40%-50% (partial charge — full charge accelerates aging)
• Temperature: 15°C - 25°C / 59°F - 77°F (high heat speeds capacity loss)
• Humidity: 30% - 50% (excess moisture causes terminal corrosion)
• Avoid: Direct sunlight, high humidity, heat sources
Mandatory Maintenance Schedule:
• Every 3-6 months: Check voltage, inspect for swelling, check connector corrosion
• Every 6 months: Perform a full charge/discharge cycle to maintain cell activity
• Annually: Assess whether replacement is needed (even before cycle limit)
🏥 Hospitals/Clinics: Equip emergency vehicles and resuscitation rooms with dedicated battery spare kits. Record each battery's "last inspection date" and "scheduled replacement date." -
How do I calibrate a new patient monitor battery?Battery calibration ensures accurate remaining-runtime display. Perform every 3-6 months:
Step 1 — Full Charge:
Insert battery and charge to 100% using the original charger. Do not use the device during charging.
Step 2 — Full Discharge:
Unplug the charger. Run the monitor until it automatically powers down. Allow the device to rest for 30 minutes.
Step 3 — Second Full Charge:
Reconnect the original charger. Charge to 100% without interruption. Do not use the device until charging completes.
Post-Calibration:
Observe whether the battery display is stable. Record this calibration date and set a reminder for the next calibration.
⚠️ Compatible Brands: Philips IntelliVue, GE CARESCAPE, Mindray, NIHON KOHDEN, and most other patient monitor brands. For brand-specific procedures, refer to the device user manual. -
Will the equipment recognize the replacement battery?Yes. KingSener medical replacement batteries are specifically designed for perfect OEM compatibility:
1. Smart BMS Chips:
Each battery includes an integrated Battery Management System (BMS) chip that communicates precisely with the device's host system — preventing "unrecognized battery" errors and ensuring accurate power readings.
2. OEM Specification Matching:
Identical voltage, capacity, and connector definitions. Plug-and-play — no device reconfiguration required.
3. Compatibility Testing:
All batteries undergo multi-brand device compatibility testing before shipping. Our compatibility database is continuously updated.
Common Questions:
• "Non-original battery" warning? → Normal and does not affect functionality
• Battery percentage inaccurate? → Perform calibration (see above)
• Device won't power on? → Check contacts and charger; contact customer service if needed